China factory Ybbp355m-160kw 750rpm Explosion-Proof Frequency Conversion Speed Control Three Phase AC Motor with Great quality

Product Description

YBBP series of explosion-proof frequency control three-phase  asynchronous motor is our company on the basis of YB3 series motors,combined with the current  state,internal and external  electromagnetic structure,technology,materials and other aspects of the new technology and new product development. It  is characterized  by the use of motor and frequency converter,can achieve a wide range of smooth stepless speed regulation,in which  the frequency  rallge of 5-50Hz for constant torque converter,50-100Hz for constant power frequency conversion,motor with axial flow fan,ensure that the cooling effect at different  speeds. to ensure motor safety,normal operation.
The rotor of the motor is made of cast aluminum. After balance verification, the motor runs smoothly, with small vibration and low noise.This series motor power rating,installation size to meet the standard of the International Electrotechnical Commission(IEC) and the corresponding relationship with Germany DIN4267 standard is the same,is conducive to supporting the export of equipment and the introduction of equipment spreparts.This series of explosion-proof frequency control three-phase asynchronous motor and frequency conversion device constitute the speed control system and other speed control mode compared with energy-saving effect is remarkable,the speed performance is good ,the speed range is wide,with low noise,vibration,can be used with all kinds of domestic and foreign inverter,help to achieve automatic control.

Frame size: 80-355mm;
Output: 0.55-315kw;
Poles: 2-4-6-8-10;
protection class: IP55/IP56/IP65/IP66
 
ExdI, Ex d IIA T4 Gb, Ex d IIB T4 Gb

duty: S1,
Voltage: 3 phase 220-1000V (50hz or 60hz)
5-50hz(60hz): constant torque;
>50hz(60hz): constant output;

The motor can undergo overload of 160% at rated rotor torque for 1 minute.
The motor torque appears as smooth at lower speed and the motor runs without creep.

The motor can guarantee rated rotor torque output at frequency or 5hz by voltage rising of frequency converter device and not go so far as to be burned as heating.

IC416, cast iron vessel.

Induction Electric Motors Type YBBP
Height of an axis, mm Power, kW at frequency of rotation The size of a shaft, mm at frequency of rotation The connecting sizes, mm
2р=2 2р=4 2р=6 2р=8 2p=2 others
H 3000 1500 1000 750 DxE B C A K M nxS P N
min -1 min -1 min -1 min -1
80M1 0.75 0.55 0.37 x 19×40 100 50 125 10 165 4×12 200 130
80M2 1.1 0.75 0.55 x
90S 1.5 1.1 0.75 x 24×50 100 56 140 10 165 4×12 200 130
90L 2.2 1.5 1.1 x 125
100L 3 2.2/3 1.5 1.1 28×60 140 63 160 12 215 4×14.5 250 180
112М 4 4 2.2 1.5 28×60 140 70 190 12 215 4×14.5 250 180
132S 5.5/7.5 5.5 3 2.2 38×80 140 89 216 12 265 4×14.5 300 230
132М x 7.5 4/5.5 3 178
160M 11/15 11 7.5 4/5.5 42×110 210 108 254 15 300 4×18.5 350 250
160L 18.5 15 11 7.5 254
180M 22 18.5 х х 48×110 241 121 279 15 300 4×18.5 350 250
180L х 22 15 11 279
200L 30/37 30 18.5/22 15 55×110 305 133 318 19 350 4×18.5 400 300
225S х 37 x 18.5 55×110 60×140 286 149 356 19 400 8×18.5 450 350
225М 45 45 30 22 311
250М 55 55 37 30 60×140 65×140 349 168 406 24 500 8×18.5 550 450
280S 75 75 45 37 65×140 75×140 368 190 457 24 500 8×18.5 550 450
280М 90 90 55 45 419
315S 110 110 75 55 65×140 80×170 406 216 508 28 600 8×24 660 550
315М 132 132 90 75 457
315L 160/200 160/200 110/132 90/110 508
355S 185/200 185/200 160 132 75×140 95×170 500 254 610 28 740 8×24 800 680
355M 220/250 220/250 185/200 160 560
355L 280/315 280/315 220/250 185/200 630

 

Application: Industrial
Speed: Variable Speed
Number of Stator: Three-Phase
Customization:
Available

|

.shipping-cost-tm .tm-status-off{background: none;padding:0;color: #1470cc}

Shipping Cost:

Estimated freight per unit.







about shipping cost and estimated delivery time.
Payment Method:







 

Initial Payment



Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.

induction motor

How do variable frequency drives (VFDs) impact the performance of AC motors?

Variable frequency drives (VFDs) have a significant impact on the performance of AC motors. A VFD, also known as a variable speed drive or adjustable frequency drive, is an electronic device that controls the speed and torque of an AC motor by varying the frequency and voltage of the power supplied to the motor. Let’s explore how VFDs impact AC motor performance:

  • Speed Control: One of the primary benefits of using VFDs is the ability to control the speed of AC motors. By adjusting the frequency and voltage supplied to the motor, VFDs enable precise speed control over a wide range. This speed control capability allows for more efficient operation of the motor, as it can be operated at the optimal speed for the specific application. It also enables variable speed operation, where the motor speed can be adjusted based on the load requirements, resulting in energy savings and enhanced process control.
  • Energy Efficiency: VFDs contribute to improved energy efficiency of AC motors. By controlling the motor speed based on the load demand, VFDs eliminate the energy wastage that occurs when motors run at full speed even when the load is light. The ability to match the motor speed to the required load reduces energy consumption and results in significant energy savings. In applications where the load varies widely, such as HVAC systems, pumps, and fans, VFDs can provide substantial energy efficiency improvements.
  • Soft Start and Stop: VFDs offer soft start and stop capabilities for AC motors. Instead of abruptly starting or stopping the motor, which can cause mechanical stress and electrical disturbances, VFDs gradually ramp up or down the motor speed. This soft start and stop feature reduces mechanical wear and tear, extends the motor’s lifespan, and minimizes voltage dips or spikes in the electrical system. It also eliminates the need for additional mechanical devices, such as motor starters or brakes, improving overall system reliability and performance.
  • Precision Control and Process Optimization: VFDs enable precise control over AC motor performance, allowing for optimized process control in various applications. The ability to adjust motor speed and torque with high accuracy enables fine-tuning of system parameters, such as flow rates, pressure, or temperature. This precision control enhances overall system performance, improves product quality, and can result in energy savings by eliminating inefficiencies or overcompensation.
  • Motor Protection and Diagnostic Capabilities: VFDs provide advanced motor protection features and diagnostic capabilities. They can monitor motor operating conditions, such as temperature, current, and voltage, and detect abnormalities or faults in real-time. VFDs can then respond by adjusting motor parameters, issuing alerts, or triggering shutdowns to protect the motor from damage. These protection and diagnostic features help prevent motor failures, reduce downtime, and enable predictive maintenance, resulting in improved motor reliability and performance.
  • Harmonics and Power Quality: VFDs can introduce harmonics into the electrical system due to the switching nature of their operation. Harmonics are undesirable voltage and current distortions that can impact power quality and cause issues in the electrical distribution network. However, modern VFDs often include built-in harmonic mitigation measures, such as line reactors or harmonic filters, to minimize harmonics and ensure compliance with power quality standards.

In summary, VFDs have a profound impact on the performance of AC motors. They enable speed control, enhance energy efficiency, provide soft start and stop capabilities, enable precision control and process optimization, offer motor protection and diagnostic features, and address power quality considerations. The use of VFDs in AC motor applications can lead to improved system performance, energy savings, increased reliability, and enhanced control over various industrial and commercial processes.

induction motor

What are the common signs of AC motor failure, and how can they be addressed?

AC motor failure can lead to disruptions in various industrial and commercial applications. Recognizing the common signs of motor failure is crucial for timely intervention and preventing further damage. Here are some typical signs of AC motor failure and potential ways to address them:

  • Excessive Heat: Excessive heat is a common indicator of motor failure. If a motor feels excessively hot to the touch or emits a burning smell, it could signify issues such as overloaded windings, poor ventilation, or bearing problems. To address this, first, ensure that the motor is properly sized for the application. Check for obstructions around the motor that may be impeding airflow and causing overheating. Clean or replace dirty or clogged ventilation systems. If the issue persists, consult a qualified technician to inspect the motor windings and bearings and make any necessary repairs or replacements.
  • Abnormal Noise or Vibration: Unusual noises or vibrations coming from an AC motor can indicate various problems. Excessive noise may be caused by loose or damaged components, misaligned shafts, or worn bearings. Excessive vibration can result from imbalanced rotors, misalignment, or worn-out motor parts. Addressing these issues involves inspecting and adjusting motor components, ensuring proper alignment, and replacing damaged or worn-out parts. Regular maintenance, including lubrication of bearings, can help prevent excessive noise and vibration and extend the motor’s lifespan.
  • Intermittent Operation: Intermittent motor operation, where the motor starts and stops unexpectedly or fails to start consistently, can be a sign of motor failure. This can be caused by issues such as faulty wiring connections, damaged or worn motor brushes, or problems with the motor’s control circuitry. Check for loose or damaged wiring connections and make any necessary repairs. Inspect and replace worn or damaged motor brushes. If the motor still exhibits intermittent operation, it may require professional troubleshooting and repair by a qualified technician.
  • Overheating or Tripping of Circuit Breakers: If an AC motor consistently causes circuit breakers to trip or if it repeatedly overheats, it indicates a problem that needs attention. Possible causes include high starting currents, excessive loads, or insulation breakdown. Verify that the motor is not overloaded and that the load is within the motor’s rated capacity. Check the motor’s insulation resistance to ensure it is within acceptable limits. If these measures do not resolve the issue, consult a professional to assess the motor and its electrical connections for any faults or insulation breakdown that may require repair or replacement.
  • Decreased Performance or Efficiency: A decline in motor performance or efficiency can be an indication of impending failure. This may manifest as reduced speed, decreased torque, increased energy consumption, or inadequate power output. Factors contributing to decreased performance can include worn bearings, damaged windings, or deteriorated insulation. Regular maintenance, including lubrication and cleaning, can help prevent these issues. If performance continues to decline, consult a qualified technician to inspect the motor and perform any necessary repairs or replacements.
  • Inoperative Motor: If an AC motor fails to operate entirely, there may be an issue with the power supply, control circuitry, or internal motor components. Check the power supply and connections for any faults or interruptions. Inspect control circuitry, such as motor starters or contactors, for any damage or malfunction. If no external faults are found, it may be necessary to dismantle the motor and inspect internal components, such as windings or brushes, for any faults or failures that require repair or replacement.

It’s important to note that motor failure causes can vary depending on factors such as motor type, operating conditions, and maintenance practices. Regular motor maintenance, including inspections, lubrication, and cleaning, is essential for early detection of potential failure signs and for addressing issues promptly. When in doubt, it is advisable to consult a qualified electrician, motor technician, or manufacturer’s guidelines for appropriate troubleshooting and repair procedures specific to the motor model and application.

induction motor

What are the key advantages of using AC motors in industrial applications?

AC motors offer several key advantages that make them highly suitable for industrial applications. Here are some of the main advantages:

  1. Simple and Robust Design: AC motors, particularly induction motors, have a simple and robust design, making them reliable and easy to maintain. They consist of fewer moving parts compared to other types of motors, which reduces the likelihood of mechanical failure and the need for frequent maintenance.
  2. Wide Range of Power Ratings: AC motors are available in a wide range of power ratings, from small fractional horsepower motors to large industrial motors with several megawatts of power. This versatility allows for their application in various industrial processes and machinery, catering to different power requirements.
  3. High Efficiency: AC motors, especially modern designs, offer high levels of efficiency. They convert electrical energy into mechanical energy with minimal energy loss, resulting in cost savings and reduced environmental impact. High efficiency also means less heat generation, contributing to the longevity and reliability of the motor.
  4. Cost-Effectiveness: AC motors are generally cost-effective compared to other types of motors. Their simple construction and widespread use contribute to economies of scale, making them more affordable for industrial applications. Additionally, AC motors often have lower installation and maintenance costs due to their robust design and ease of operation.
  5. Flexible Speed Control: AC motors, particularly induction motors, offer various methods for speed control, allowing for precise adjustment of motor speed to meet specific industrial requirements. Speed control mechanisms such as variable frequency drives (VFDs) enable enhanced process control, energy savings, and improved productivity.
  6. Compatibility with AC Power Grid: AC motors are compatible with the standard AC power grid, which is widely available in industrial settings. This compatibility simplifies the motor installation process and eliminates the need for additional power conversion equipment, reducing complexity and cost.
  7. Adaptability to Various Environments: AC motors are designed to operate reliably in a wide range of environments. They can withstand variations in temperature, humidity, and dust levels commonly encountered in industrial settings. Additionally, AC motors can be equipped with protective enclosures to provide additional resistance to harsh conditions.

These advantages make AC motors a popular choice for industrial applications across various industries. Their simplicity, reliability, cost-effectiveness, energy efficiency, and speed control capabilities contribute to improved productivity, reduced operational costs, and enhanced process control in industrial settings.

China factory Ybbp355m-160kw 750rpm Explosion-Proof Frequency Conversion Speed Control Three Phase AC Motor   with Great quality China factory Ybbp355m-160kw 750rpm Explosion-Proof Frequency Conversion Speed Control Three Phase AC Motor   with Great quality
editor by CX 2023-11-29

Leave a Reply

Your email address will not be published. Required fields are marked *