China supplier Air Conditioner Cbb65 AC Motor Run Capacitor Water Cooled Capacitor vacuum pump and compressor

Product Description

 

 

 

 

Recommend view more >>

 

 

 

 

 

Model Number:

CBB65 air conditioner capacitor

Type

Polypropylene film capacitor

Safety approvals:

CQC/VDE/TUV/CL

Approval standard

GB/T3667,EN65712

Climatic category

25/70/21,25/85/21,40/70/21,40/85/21

Rated voltage

150VAC~600VAC(50-60Hz)

Capacitance range

3uf~100uf

Capacitance tolerance

+_5%(J),+_10%(K),+10%(U),-5%(U)

Testing voltage

 

Between terminals

2*Un(VAC)/5s

Between terminals and case

2*Un+1000(VAC)/5s(>=2000VAC)

Insulation Resistance(20)

 

Between terminals

>=2000MΩ,UF(500VDC,5s)

Tangent of loss angle(20)

<=0.002(100Hz)

Class of safety protection

S0/S3

Fault Currency

10,000AFC(UL810)

Place of CHINAMFG

CHINA

Packing

More pieces in 1 inner box or polybag as customer request.

Color

accept customization

Supplier type

OEM factory

Capacitance(uf)

250/300VAC

 

 

400-450VAC

 

 

 

Cylindrical

 

Ocal

Cylindrical

 

Ocal

 

D

H

L*W*H

H

D

L*W*H

10uf

40

55

51.5*31.5*65

30

60

51.5*31.5*65

15uf

40

55

51.5*31.5*65

35

60

/

20uf

40

65

51.5*31.5*65

40

60

51.5*31.5*75

25uf

40

65

51.5*31.5*65

40

60

51.5*31.5*85

30uf

/

/

/

40

70

71.5*45*75

35uf

40

75

71.5*45*75

45

70

/

40uf

/

/

/

45

70

71.5*45*85

45uf

45

75

71.5*45*75

45

80

/

50uf

45

85

71.5*45*85

45

90

71.5*45*100

60uf

45

95

71.5*45*100

50

90

/

What’s a dual run AC capacitor ?
* A capacitor is an electric component that temporarily stores an electrical charge and AC capacitor is a key component to start
air conditioner motors.
* A dual run capacitor supports “TWO” electric motors, 1 section for the condenser fan motor and the other for the compressor
motor. Beacause of technological innovation, the dual run capacitor can saves space by combining 2 capacitors into 1 case.
* Round cylinder-shaped dual run capacitors are commonly used for air conditioning, it can help in the starting of the compressor
and the condenser fan motor.
* Air conditioner capacitor is small in size, lightweight, heat resisting and anti-explosion.

Dual capacitors come in a variety of sizes, depending on the capacitance (µF or MFD) and the voltage.

1. The capacitance (µF or MFD) must be the same or stay within ±6% of its original value. Example: 45 µF cap can be substituted
by 42.3 to 47.7 µF with the same or better voltage ratings capacitor .
2. A 440 volt capacitor can be used in place of a 370 volt capacitor, as it can work better, but the 370 volt capacitor can’t be
used in place of a 440 volt capacitor.It will work for a while or will fail prematurely, because exceeding the capacitor’s
rated voltage will cause the dielectric to break down and the capacitor to short out.

“TIME” to Replace
The Dual Run AC Capacitor needs to be replaced when the following conditions occur:

1. The fan wouldn’t spin – the condenser fan motor maybe died.
2. The air conditioner is making humming sound, but no air flow.
3. Air conditioner stopped cooling – the compressor in the condenser maybe not coming on.

“SUPER EASY” to Install

* First, Shut off power to the A/C at both the thermostat and the breaker box. Secondly, taking out the capacitor.
* What’s important, make sure you know which wire is for which terminal – 3 terminals on the top are labeled “Herm”/”H” for
the compressor motor, “Fan”/”F” for the fan and “C” for the common line.
* Direct replacement, no need to change wiring or adapter.
* Last but not least, self-install will save you a substantial amount of money!

What is a starting capacitor and a running capacitor for a motor?
As we all know, a single-phase AC motor is not like a three-phase motor. It can turn when it is powered. It needs a starting torque to rotate, and the clockwise and anti-clockwise of this torque determines the steering of the motor, and there are many
ways to start. Among them, the capacitor start is one, which is customarily called the start capacitor, and the single-phase motor needs it to rotate smoothly.
However, some single-phase motors have more than 1 capacitor, and some motors have 2 capacitors. Why? Because some motors are equipped with a starting capacitor and a running capacitor, what is going on?
The difference between start capacitors and run capacitors.
Running capacitor: It is connected to the secondary winding to form an alternating magnetic field after phase-shifting the alternating current, and forms an approximately circular elliptical rotating magnetic field with the alternating magnetic field of the main winding. So he can be the same capacitor, but its role is different.
No matter what kind of capacitor, it has a starting effect at the beginning of the motor. However, when the motor reaches about 75% of the rated speed, the starting capacitor is automatically disconnected by the centrifugal switch, and the running capacitor continues to work with the motor. The process of starting the motor is actually the process of “column phase”. Because a single-phase motor is different from a three-phase motor, there is no phase difference, and a rotating magnetic field cannot be generated. The function of the capacitor is to make the starting winding current of the motor lead the running winding by 90 electrical angles in time and space to form a phase difference. Among them, the running capacitor also plays the role of balancing the current between the main and auxiliary windings. Since the starting capacitor works for an instant and a short time, the withstand voltage is required to be above 250V, while the running capacitor needs to work for a long time, and the withstand voltage is required to be above 450V.
The starting capacitor is to make the starting coil of the single-phase motor energized at the time of starting, and then cut off after starting. The running capacitor is to make the motor perform capacitance compensation during the operation, so the starting capacitor cannot be less, and the running capacitor can not be used.
The running capacitor is the starting capacitor used when the press is working normally. When the press starts, it starts the press together with the running capacitor. After the press is turned up, the start capacitor is disconnected. The running and starting capacitors are together, but 1 of the starting capacitors is open, and the starting capacitor is useless when the motor turns. What is the difference between the starting capacitor and the running capacitor? That is the capacity of the starting capacitor is large, generally 2-5 times that of the running capacitor, while the capacity of the running capacitor is small, and the capacity difference between the 2 is huge and easy to distinguish.

/* January 22, 2571 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1

Application: Industrial
Certification: ISO9001, CE
Specification: CH86
Customization:
Available

|

.shipping-cost-tm .tm-status-off{background: none;padding:0;color: #1470cc}

Shipping Cost:

Estimated freight per unit.







about shipping cost and estimated delivery time.
Payment Method:







 

Initial Payment



Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.

induction motor

Are there environmental considerations associated with the use of AC motors?

Yes, there are several environmental considerations associated with the use of AC motors. These considerations are primarily related to energy consumption, greenhouse gas emissions, and the disposal of motors at the end of their life cycle. Let’s explore these environmental considerations in detail:

  • Energy Efficiency: AC motors can have varying levels of energy efficiency, which directly impacts their environmental impact. Motors with higher efficiency convert a larger percentage of electrical energy into useful mechanical work, resulting in reduced energy consumption. By selecting and using high-efficiency AC motors, energy usage can be minimized, leading to lower greenhouse gas emissions and reduced reliance on fossil fuels for electricity generation.
  • Greenhouse Gas Emissions: The electricity consumed by AC motors is often produced by power plants that burn fossil fuels, such as coal, natural gas, or oil. The generation of electricity from these fossil fuels releases greenhouse gases, contributing to climate change. By employing energy-efficient motors and optimizing motor systems, businesses and individuals can reduce their electricity demand, leading to lower greenhouse gas emissions and a smaller carbon footprint.
  • Motor Disposal and Recycling: AC motors contain various materials, including metals, plastics, and electrical components. At the end of their life cycle, proper disposal or recycling is important to minimize their environmental impact. Some components, such as copper windings and steel casings, can be recycled, reducing the need for new raw materials and energy-intensive manufacturing processes. It is crucial to follow local regulations and guidelines for the disposal and recycling of motors to prevent environmental pollution and promote resource conservation.
  • Manufacturing and Production: The manufacturing and production processes associated with AC motors can have environmental implications. The extraction and processing of raw materials, such as metals and plastics, can result in habitat destruction, energy consumption, and greenhouse gas emissions. Additionally, the manufacturing processes themselves can generate waste and pollutants. Motor manufacturers can mitigate these environmental impacts by adopting sustainable practices, using recycled materials, reducing waste generation, and implementing energy-efficient production methods.
  • Life Cycle Assessment: Conducting a life cycle assessment (LCA) of AC motors can provide a holistic view of their environmental impact. An LCA considers the environmental aspects associated with the entire life cycle of the motor, including raw material extraction, manufacturing, transportation, use, and end-of-life disposal or recycling. By analyzing the different stages of the motor’s life cycle, stakeholders can identify opportunities for improvement, such as optimizing energy efficiency, reducing emissions, and implementing sustainable practices.

To address these environmental considerations, governments, organizations, and industry standards bodies have developed regulations and guidelines to promote energy efficiency and reduce the environmental impact of AC motors. These include efficiency standards, labeling programs, and incentives for the use of high-efficiency motors. Additionally, initiatives promoting motor system optimization, such as proper motor sizing, maintenance, and control, can further enhance energy efficiency and minimize environmental impact.

In summary, the environmental considerations associated with the use of AC motors include energy efficiency, greenhouse gas emissions, motor disposal and recycling, manufacturing processes, and life cycle assessment. By prioritizing energy efficiency, proper disposal, recycling, and sustainable manufacturing practices, the environmental impact of AC motors can be minimized, contributing to a more sustainable and environmentally conscious approach to motor usage.

induction motor

What are the safety considerations when working with or around AC motors?

Working with or around AC motors requires careful attention to safety to prevent accidents, injuries, and electrical hazards. Here are some important safety considerations to keep in mind:

  • Electrical Hazards: AC motors operate on high voltage electrical systems, which pose a significant electrical hazard. It is essential to follow proper lockout/tagout procedures when working on motors to ensure that they are de-energized and cannot accidentally start up. Only qualified personnel should perform electrical work on motors, and they should use appropriate personal protective equipment (PPE), such as insulated gloves, safety glasses, and arc flash protection, to protect themselves from electrical shocks and arc flash incidents.
  • Mechanical Hazards: AC motors often drive mechanical equipment, such as pumps, fans, or conveyors, which can present mechanical hazards. When working on or near motors, it is crucial to be aware of rotating parts, belts, pulleys, or couplings that can cause entanglement or crushing injuries. Guards and safety barriers should be in place to prevent accidental contact with moving parts, and proper machine guarding principles should be followed. Lockout/tagout procedures should also be applied to the associated mechanical equipment to ensure it is safely de-energized during maintenance or repair.
  • Fire and Thermal Hazards: AC motors can generate heat during operation, and in some cases, excessive heat can pose a fire hazard. It is important to ensure that motors are adequately ventilated to dissipate heat and prevent overheating. Motor enclosures and cooling systems should be inspected regularly to ensure proper functioning. Additionally, combustible materials should be kept away from motors to reduce the risk of fire. If a motor shows signs of overheating or emits a burning smell, it should be immediately shut down and inspected by a qualified professional.
  • Proper Installation and Grounding: AC motors should be installed and grounded correctly to ensure electrical safety. Motors should be installed according to manufacturer guidelines, including proper alignment, mounting, and connection of electrical cables. Adequate grounding is essential to prevent electrical shocks and ensure the safe dissipation of fault currents. Grounding conductors, such as grounding rods or grounding straps, should be properly installed and regularly inspected to maintain their integrity.
  • Safe Handling and Lifting: AC motors can be heavy and require proper handling and lifting techniques to prevent musculoskeletal injuries. When moving or lifting motors, equipment such as cranes, hoists, or forklifts should be used, and personnel should be trained in safe lifting practices. It is important to avoid overexertion and use proper lifting tools, such as slings or lifting straps, to distribute the weight evenly and prevent strain or injury.
  • Training and Awareness: Proper training and awareness are critical for working safely with or around AC motors. Workers should receive training on electrical safety, lockout/tagout procedures, personal protective equipment usage, and safe work practices. They should be familiar with the specific hazards associated with AC motors and understand the appropriate safety precautions to take. Regular safety meetings and reminders can help reinforce safe practices and keep safety at the forefront of everyone’s minds.

It is important to note that the safety considerations mentioned above are general guidelines. Specific safety requirements may vary depending on the motor size, voltage, and the specific workplace regulations and standards in place. It is crucial to consult relevant safety codes, regulations, and industry best practices to ensure compliance and maintain a safe working environment when working with or around AC motors.

induction motor

Are there different types of AC motors, and what are their specific applications?

Yes, there are different types of AC motors, each with its own design, characteristics, and applications. The main types of AC motors include:

  1. Induction Motors: Induction motors are the most commonly used type of AC motor. They are robust, reliable, and suitable for a wide range of applications. Induction motors operate based on the principle of electromagnetic induction. They consist of a stator with stator windings and a rotor with short-circuited conductive bars or coils. The rotating magnetic field produced by the stator windings induces currents in the rotor, creating a magnetic field that interacts with the stator field and generates torque. Induction motors are widely used in industries such as manufacturing, HVAC systems, pumps, fans, compressors, and conveyor systems.
  2. Synchronous Motors: Synchronous motors are another type of AC motor commonly used in applications that require precise speed control. They operate at synchronous speed, which is determined by the frequency of the AC power supply and the number of motor poles. Synchronous motors have a rotor with electromagnets that are magnetized by direct current, allowing the rotor to lock onto the rotating magnetic field of the stator and rotate at the same speed. Synchronous motors are often used in applications such as industrial machinery, generators, compressors, and large HVAC systems.
  3. Brushless DC Motors: While the name suggests “DC,” brushless DC motors are actually driven by AC power. They utilize electronic commutation instead of mechanical brushes for switching the current in the motor windings. Brushless DC motors offer high efficiency, low maintenance, and precise control over speed and torque. They are commonly used in applications such as electric vehicles, robotics, computer disk drives, aerospace systems, and consumer electronics.
  4. Universal Motors: Universal motors are versatile motors that can operate on both AC and DC power. They are designed with a wound stator and a commutator rotor. Universal motors offer high starting torque and can achieve high speeds. They are commonly used in applications such as portable power tools, vacuum cleaners, food mixers, and small appliances.
  5. Shaded Pole Motors: Shaded pole motors are simple and inexpensive AC motors. They have a single-phase stator and a squirrel cage rotor. Shaded pole motors are characterized by low starting torque and relatively low efficiency. Due to their simple design and low cost, they are commonly used in applications such as small fans, refrigeration equipment, and appliances.

These are some of the main types of AC motors, each with its unique features and applications. The selection of an AC motor type depends on factors such as the required torque, speed control requirements, efficiency, cost, and environmental conditions. Understanding the specific characteristics and applications of each type allows for choosing the most suitable motor for a given application.

China supplier Air Conditioner Cbb65 AC Motor Run Capacitor Water Cooled Capacitor   vacuum pump and compressor	China supplier Air Conditioner Cbb65 AC Motor Run Capacitor Water Cooled Capacitor   vacuum pump and compressor
editor by CX 2024-05-07

Leave a Reply

Your email address will not be published. Required fields are marked *